Maintenance
TX,90,DH1756 –19–31JUL92–1/1
CHECKING AND ADJUSTING COMPRESSOR
BELT TENSION—IF EQUIPPED
1. A force of 111 N (25 lb force) halfway between pulleys
must move belt 13 mm (0.5 in.).
2. To adjust tension, loosen mounting cap screws.
3. Apply force to FRONT compressor housing only (near
the belt) until tension is correct.
4. Tighten cap screws.
TX,90,JC1060 –19–25JAN96–1/1
WELDING ON MACHINE
IMPORTANT: Disconnect battery ground strap or turn
battery disconnect switch to "OFF" to
prevent voltage spikes through
alternator or monitor.
If machine is equipped with a controller
(microprocessor) like Engine Controller
(EC), Pump and Valve Controller (PVC)
or Transmsision Controller disconnect
harness connector from controller to
prevent voltage spikes through
microprocessor.
Connect welder ground clamp close to
each weld area so electrical current
does not arc inside any bearings,
bushings or pins.
90–20
PN=186